| Product code |
MHC-V8WD2RN7-BER90 | HB-A60/CDS90GN8-B + MHA-V4W/D2N8-B2 | HB-A160/CDS90GN8-B + MHA-V16W/D2RN8-B2 |
| Heating capacity Outdoor air +35°C/ 7°C |
8 kW | 4.25 kW | 16.0 kW |
| Product type |
Air-to-water heat pump | Air-to-water heat pump | Air-to-water heat pump |
| Energy efficiency class (35°/55°) |
A +++/ A++ | A +++/ A++ | A +++/ A++ |
| SCOP |
5.35 | 4.85 | 4.62 |
| Warranty |
2 years | 2 years | 2 years |
| Wi-Fi smart remote control |
Yes | Yes | Yes |
| Operating limit (Heating) |
-25 ~ 35 °C | -25 ~ 35 °C | -25 ~ 35 °C |
| Refrigerant |
R290 | R32 | R32 |
| Power supply voltage |
380–415/3/50 V/Ph/Hz | 230/1/50 V/Ph/Hz | 380/3/50 V/Ph/Hz |
| Protection circuit breaker |
16 A | 20 A | 16 A |
| Control and monitoring via the Internet |
Yes | Yes | Yes |
| Electric auxiliary heating element |
9 kW | 3+3+3 kW | 3+3+3 kW |
| Domestic hot water boiler capacity |
Separate | Separate | Separate |
| Maximum heating water temperature |
80 °C | 65 °C | 65 °C |
| Pipe size (Liquid/Gas) |
| 6.35 + 15.9 mm | 9.52 + 15.9 mm |
| Maximum pipe length |
| 30 m | 30 m |
| COP |
| 5.20 | 4.50 |
| Auxiliary heating element power |
| 3+3+3 kW | 3+3+3 kW |
| Outdoor unit weight |
148 kg | 58 kg | 112 kg |
| Outdoor unit dimensions (width x height x depth) |
1330x1051x475 mm | 1007x712x426 mm | 1118x864x523 mm |
| Outdoor noise level |
37 dB(A) | 44 dB(A) | 55 dB(A) |
| Indoor unit weight |
| 37 kg | 39 kg |
| Indoor unit dimensions (width x height x depth) |
| 420×790×270 mm | 420×790×270 mm |