| Product code |
Domekt R 450 V C6M | MSAGBU-12HRFN8 + MOX201-12HFN8-QRD6GW | Domekt R 400 F C6M | 206679 + 207850 | 527_177 |
| Energy efficiency class |
A+ | A+++/A+++ | A+ | | A+++ |
| Approximate size of ventilated surface |
240 m² | | 200 m² | | |
| Air duct connection |
Ø 1x125, 4x160 mm | | Ø 1x125, 4x200 mm | | |
| Heating capacity (Min./Nom./Max.) |
| 0.8/3.8/6.5 kW | | | |
| Cooling capacity (Min./Nom./Max.) |
| 0.8/3.5/4.7 kW | | | |
| Product type |
| Air-to-air heat pump | | Air-to-water heat pump | Air-to-water heat pump |
| Warranty |
| 2 years | | 2 years | 5 years |
| Estonian language menu |
| Yes | | | Yes |
| Wi-Fi smart remote control |
| Yes | | | Yes |
| Operating limit (Cooling) |
| -15 ~ 50 °C | | | |
| Operating limit (Heating) |
| -25 ~ 24 °C | | -25 ~ +35 °C | -25 ~ 35 °C |
| Refrigerant |
| R32 | | R290 | R290 |
| Pipe size (Liquid/Gas) |
| 6.35 + 9.52 mm | | | |
| Maximum height difference |
| 10 m | | | |
| Maximum pipe length |
| 25 m | | 15 m | |
| Power supply voltage |
| 220-240/1/50 V/Ph/Hz | | 400/3/50 V/Ph/Hz | 400/3/50 V/Ph/Hz |
| Protection circuit breaker |
| C10 A | | 16 A | 13 A |
| SCOP (Warm/medium/cold climate) |
| 4.6 | | | |
| SEER |
| 8.5 | | | |
| Heating capacity Outdoor air +35°C/ 7°C |
| | | 3-12 kW | 8.08 kW |
| Energy efficiency class (35°/55°) |
| | | A+++/A++ | |
| SCOP |
| | | 4.9 | 4.96 |
| Active cooling option |
| | | Yes | |
| Control and monitoring via the Internet |
| | | Yes | |
| Domestic hot water boiler capacity |
| | | 184 l | Separate |
| Maximum heating water temperature |
| | | 75 °C | 75 °C |
| Indoor unit weight |
| 8.7 kg | | 106 kg | |
| Indoor unit dimensions (width x height x depth) |
| 835x295x208 mm | | | |
| Indoor unit noise level |
| 39/30/24 dB(A) | | | |
| Outdoor unit weight |
| 29.5 kg | | 140 kg | 134 kg |
| Outdoor unit dimensions (width x height x depth) |
| 765x555x303 mm | | 1270 x 1018 x 530 mm | 1083x1133x525 mm |
| Outdoor noise level |